The NanoBRET™ Target Engagement (TE) Assay measures compound binding at select target proteins within intact cells by analyzing the apparent affinity of test compounds by competitive displacement of a NanoBRET™ tracer reversibly bound to a NanoLuc® fusion protein in cells. In the first step of the NanoBRET™ TE Assay, a fixed concentration of tracer is added to cells expressing the desired NanoLuc® fusion protein. Introduction of competing compounds results in a dose-dependent decrease in NanoBRET™ energy transfer for estimating intracellular affinity at the target protein. The NanoBRET™ TE Intracellular HDAC Assay assesses compound binding to a histone deacetylase (HDAC)-NanoLuc® luciferase fusion protein.