GloMax® Navigator Microplate Luminometer

GM2000 Luminescence Detection Plate Reader

Easy-to-Use, Luminescence Plate Reader

  • Plate reading luminometer for convenient detection of bioluminescence
  • Developed and optimized with Promega cell and gene reporter assays
  • Over 30 preloaded assay protocols

Choose an option

Catalog number selected: GM2000

Your price:
Add to Cart
This product is discontinued
GloMax® Navigator Microplate Luminometer
1 each
Your price: Log in
Change Configuration

Experience the difference a sensitive, ready-to-use luminometer can make in your lab 

The GloMax® Navigator is an easy-to-use microplate luminometer integrated with Promega chemistries for superior luminescence assay performance. The GloMax® Navigator comes ready to use—simply unpack it, plug it in and begin your experiments. You can also interpret results using integrated data analysis software.

GM2000 Luminometer & Luminescence Detection

Performance

GM2000 Microplate Luminometer Plate Reader
Easy-to-Use

  • Simple touch screen navigation with full PC capabilities.
  • Choose from over 30 preloaded protocols and spend less time optimizing.
  • Build custom protocols using the intuitive drag-and-drop interface.
  • Export data to a network, cloud or any drive desired.
GM2000 Luminescence-Detection Plate Reader
Superior Performance

  • Highest instrument sensitivity to measure the lowest assay signals.
  • Low cross-talk between wells gives you better, more usable results.
  • Broad dynamic range of the instrument extends the linear range of your assay.
GM2000 Microplate Luminometer & Fluorometer
Quality

  • IQ/OQ Service available.
  • Provides the required technical elements of a part 11 compliant system when used with the appropriate laboratory workflow:
    • User Authentication and Authorization
    • Data Integrity and Protection
    • Electronic Signatures
    • Audit Trails

Accurate Results from Every Well

There are three ways that detection instruments can affect how much useful information you get from each plate. Poor sensitivity may cause you to miss low-level samples that could be the “hit” you are looking for. Letting the signal from bright wells spill into adjacent wells allows crosstalk to occur and skews your experimental results. And a narrow detection range limits the accuracy and reproducibility that your work requires. With the GloMax® plate readers, you can rest easy and have confidence in your results.
GloMax Instruments Sensitivity Detects Signals From More Wells
Superior sensitivity so you don’t miss hits

The Glomax® instruments offer superior sensitivity and auto-gain adjustment letting you measure weak and strong signals on the same plate.

GloMax Instruments Minimize CrossTalk
Masking so crosstalk doesn’t mislead your results

The masking design of the GloMax® instruments means you can be confident that the results for each well are not skewed by signal from neighboring wells.

GloMax Instruments Detect a Broad Signal Range
Broad detection range so you don’t limit your experiments

With the broad detection range of the GloMax® instruments, you can measure signals ranging from high intensity to near physiological levels.

Viability and Cytotoxicity Workflow

Design

arrowPlate and treat your cells, design your controls and chose a pre-programmed protocol or design your own protocol on the GloMax® Navigator System.

Develop

arrowMeasure your luminescence assay. Perform a kinetic study to measure cellular or reporter response over time. Take advantage of the GloMax® Navigator's optional dual injectors to make data collection a breeze.

Detect

The GloMax® Navigator is an easy step into plate-reading detection. Collect your data. Benefit from the heat map display of collected values and automatic data analysis. Export results and analyses to the network, cloud or any desired drive.

Reporter Gene Assay Workflow

Design

arrowUse predesigned vectors for a variety of important biological pathways or design your own assay with a selection of purpose-built reporter vectors from Promega.

Deliver

arrowEfficient transfection is necessary to accurately measure small biological changes and these changes should not be masked by toxic effects from the transfection reagent. FuGENE® HD allows transfection of optimized reporter genes into many model systems with minimal impact on physiology.

Develop

arrowLuciferase activity can be detected at extremely low expression levels. This sensitivity and ease of detection makes luciferase-based assay highly versatile and scalable for many applications. GloMax® Navigator for high-performance and ease-of-use.

Detect

The GloMax® Navigator is an easy step into plate-reading detection. Collect your data. Benefit from the heat map display of collected values and automatic data analysis. Export results and analyses to the network, cloud or any desired drive.

Service and Support

One Call Supports It All

Promega supplies both the reagents and the instrument, so one call to Promega answers any questions you may have about assay chemistries or instrument performance.

Contact Technical Services

 

Ensure Minimal Instrument Downtime

  • Field Support and Loaner Programs
  • Service Packages
  • IQ and OQ Packages

Warranty and Service Agreements

  • Backed by a one-year warranty.
  • Additional warranty and service agreements are available.
  • For more information contact Promega Technical Services
Instrument Service and Support Instrument Registration
GM2000 Luminescence Detection Luminometer

Design Features

Instrument Specifications
Detection Modes Luminescence
Sample Format 96-well plates
Tablet PC Windows®8 Tablet PC with USB connection to instrument
Dimensions 18.6in (47.2cm) width
20.0in (50.8cm) depth
9.4in (23.9cm) height without Tablet and PC mounted
18in (45.7cm) height with Tablet and PC mounted
Weight Approximately 40lbs. (18.1kg)
Power Requirements 120VA, 50/60 HZ
Warranty 1-year parts and labor warranty included
Regulatory Compliance For Research Use Only. Not for use in Diagnostic Procedures
Luminescence Module Specifications
Detector Top-reading, head-on photon counting photomultiplier tube (PMT)
Wavelength Range 350–700nm
Detection Limit 1.5 × 10-21 moles of luciferase
Linear Dynamic Range >9 logs
Cross-talk Less than 3 × 10-5 (white, 96-well plate, Corning 3912)
Injector System Specifications
Number of injectors (optional) Two injectors
Dispense Volume Range 5–200µl in 1µl increments
Plate Compatibility 96-well plates
Injection Speed 20–500µl per second
Waste Collection Tray Volume Approximately 50ml
Void Volume 500µl
PC Requirements
Operating System Windows® 8, 64 bit, with USB connection to instrument
RAM 2GB
Disk Space 64GB
Other Requirements Microsoft.NET 4.0 Framework (full version), Microsoft Excel 2013 Professional

Available Separately

Product Catalog #
Dual Injector Pump Station Upgrade for GloMax® Navigator SA1304
GloMax® Navigator Sales Rental E5302
GloMax® Navigator Installation Qualification SA1305
GloMax® Navigator Operational Qualification SA1306
GloMax® Navigator Installation and Operational Qualification SA1307
GloMax® Navigator Preventive Maintenance SA1308
GloMax® Navigator Standard Service Agreement SA1301

Specifications

You are viewing: GM2000 Change Configuration

Certificate of Analysis

See all certificates for GM2000 Search
View more results
No results
Loading…

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

DD

See Protocol for storage recommendations.

Patents and Disclaimers

Patent Pending.

Specifications

You are viewing: GM2010 Change Configuration

Certificate of Analysis

See all certificates for GM2010 Search
View more results
No results
Loading…

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

DD

See Protocol for storage recommendations.

Patents and Disclaimers

Patent Pending.

Choose your country

Americas

Brazil
Canada
United States

Pacific Asia

Australia
India
Japan
Korea, Republic of
Singapore

Europe

Austria
Belgium
Denmark
Estonia
Finland
France
Germany
Iceland
Italy
Luxembourg
Netherlands
Norway
Poland
Spain
Sweden
Switzerland
United Kingdom