new-kit-box new-kit-box new-kit-box new-kit-box new-kit-box new-kit-box

Measure Immunogenicity of Single-Stranded mRNA Samples

  • Specific: No interference from other TLRs
  • Differentiable: Response is sequence- and size-specific
  • Simple: Add-mix-read protocol
  • Convenient: Reagents provided in thaw-and-use format

TLR7 Bioassay

  Catalog No. Product Name   Size Price Qty  
CS3633B05 Early Access TLR7 Bioassay View Specifications 1 each     Please Enquire
CS3633B07 Early Access TLR7 Bioassay 5X View Specifications 1 each     Please Enquire
CS3633B02 Early Access TLR7 Bioassay, Propagation Model View Specifications 1 each     Please Enquire

Early Access = This product is available under our Early Access program - Learn More

Catalog (FT) = This product is available under our Catalog (FT) program - Learn More

TLR8 Bioassay

  Catalog No. Product Name   Size Price Qty  
CS3633B12 Early Access TLR8 Bioassay View Specifications 1 each     Please Enquire
CS3633B14 Early Access TLR8 Bioassay 5X View Specifications 1 each     Please Enquire
CS3633B09 Early Access TLR8 Bioassay, Propagation Model View Specifications 1 each     Please Enquire

Early Access = This product is available under our Early Access program - Learn More

Catalog (FT) = This product is available under our Catalog (FT) program - Learn More

Overview
Protocols
Specifications
Resources
Related Products

Functional Detection of ssRNA and Small-Molecule Agonists

TLR7 and TLR8 are endosomal pattern-recognition receptors that recognize single-stranded RNA (ssRNA) and small-molecule agonists, playing a key role in antiviral immunity and innate immune activation. Bioassays targeting TLR7 and TLR8 provide mechanism-of-action-based platforms for the detection and quantitation of agonist activity in research, drug development and quality control settings. These assays enable precise functional readouts of receptor activation, offering biologically relevant data that cannot be captured by physicochemical methods alone.

Assay Utility and Format Advantages

Available in thaw-and-use reporter cell formats, TLR7 and TLR8 bioassays streamline immunostimulatory profiling by eliminating the need for primary cells or complex culture systems. Their sensitivity to ssRNA structure, sequence context and delivery formulations makes them ideal for screening adjuvants, characterizing innate immune modulators and assessing off-target immunogenicity in RNA-based therapeutics. These bioassays facilitate robust, reproducible assessments of TLR-mediated activity, supporting both early-stage discovery and lot-release testing.

Single-Stranded mRNA Detection and Functional Activity

Illustration showing the principle of the TLR7 and TLR8 Bioassays.

Principle of TLR7 and TLR8 Bioassays. TLR7 and TLR8 reporter cells uptake ssRNA or other synthetic TLR7 and TLR8 agonist, respectively, through endocytosis. The binding of the ssRNA to endosomal TLR7 or TLR8 leads to the activation of the TLR7- or TLR8-responsive promoter, which drives luciferase reporter expression and luminescent output.


Assay Workflow: Standardized Reagents to Improve Your Results

Illustration showing the TLR7 and TLR8 Bioassay workflow.
  • Thaw-and-use cell format provides significant time and labor savings over traditional methods while reducing variability.
  • User-friendly protocol for quicker enablement.
  • Easily amenable to high-throughput workflows.

Assays are Specific to TLR7 or TLR8 Activation

Line graph showing results of the TLR7 Bioassay performed with R848 (agonist).
Line graph showing results of the TLR8 Bioassay performed with R848 (agonist).

The TLR7 Bioassays and TLR8 Bioassays are specific to ssRNA detection. The TLR7 Bioassay effector cells (Panel A) and TLR8 Bioassay effector cells (Panel B) were incubated with increasing concentrations of the agonist R848. Luminescence was measured as a reporter of activation with parental cells lacking TLR7 or TLR8 serving as negative controls. Specific signal was observed only in receptor-expressing effector cells, confirming assay specificity to TLR7 or TLR8 activation.

Assays are Sequence- and Size-Specific

Line graph showing results of the TLR7 Bioassay performed with ssRNAs of various length complexed with lipid transfection reagents.
Line graph showing results of the TLR8 Bioassay performed with ssRNAs of various length complexed with lipid transfection reagents.

TLR7 and TLR8 Bioassays detect ssRNA in a sequence- and size-dependent manner. ssRNAs of various length were complexed with lipid transfection reagents and tested in the TLR7 (Panel A) and TLR8 (Panel B) Bioassays. ssRNA sequence length from longest to shortest is as follows: Firefly Luciferase > Poly(U) > ssRNA40 > ORN 06. Size-dependent differences were seen with TLR7 responding to the longer and more “U”-rich sequences. ssRNAs were either vendor-formulated or complexed in-house with Lipofectamine™ MessengerMAX™. Data demonstrate that TLR7 and TLR8 activation is influenced by both sequence and length of the RNA stimulus.

Protocols

No protocols available

Specifications

Catalog Number:

What's in the box?

Item Part # Size

TLR7 Effector Cells

CS3633B03 1 × 0.5ml

Fetal Bovine Serum

J121A 1 × 4ml

DMEM with 4.5g/L Glucose, L-Glutamine, Sodium Pyruvate

J236A 1 × 60ml

Bio-Glo-NL™ Luciferase Assay Buffer

J308A 1 × 10ml

Bio-Glo-NL™ Luciferase Assay Substrate

J309A 1 × 200μl

Certificate of Analysis

Search by lot number

Patents and Disclaimers

Promega Cell Line Limited Use Label License (LULL)


BY USE OF THIS MATERIAL, RECIPIENT AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE.


  • 1. Usage and Transfer Restrictions:
    • 1.1. Recipient may use this material for research use only, which includes but is not limited to drug discovery and development, quality assurance testing and product release assays. No transfer, resale or commercial use of this material is allowed without the written consent of Promega Corporation.
    • 1.2. “Commercial use” means any and all uses of this material or derivatives by recipient for monetary or other consideration, including product manufacture, providing a service, information or data to unaffiliated third parties and resale of the material for any use.
  • 2. Modification Restrictions:
    • 2.1. Recipient shall have no right to modify, derivatize or otherwise create variations of the nucleotide sequence of any proprietary gene, including but not limited to luciferase, NanoBiT® technology (e.g., HiBiT), HaloTag® technology or genes stably transfected within the cells.
    • 2.2. Recipient shall have no right to genetically engineer or otherwise modify the cell line.
  • 3. Propagation and Storage:
    • 3.1. The recipient may not propagate the cells, unless material is marked as Propagation Model, Cell Bank or Master Cell Bank; then recipient may propagate and store the cells for long-term use.
  • 4. For all determinations of luminescence or other assay-related activity of this material and its derivatives, recipient must either:
    • 4.1. Use the detection systems specified in the protocol or data report and purchased from Promega for all luminescence assays when using this material; or
    • 4.2. Contact Promega to obtain a license for use of this material with reagents other than a Bio-Glo™ branded luciferase reagent, including but not limited to:
      • 4.2.1 Bio-Glo™, Bio-Glo-NL™, Bio-Glo-NB™ TCK, Bio-Glo-NB™ VLP, Bio-Glo-NB™ Lytic
  • 5. For uses of this material for energy transfer (such as bioluminescence resonance energy transfer), recipient must:
    • 5.1. Use NanoBRET™-branded luminescent assay reagents (LARs; e.g., NanoBRET™ Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine™/Inhibitor for all determinations of luminescent activity by this material and its derivatives; and
    • 5.2. Use NanoBRET™-branded energy acceptors (e.g., NanoBRET™ tracers, NanoBRET™ dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this material and its derivatives; or
    • 5.3. Contact Promega to obtain a license for the use of the material and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
  • 6. For uses of HaloTag® Technology in this material, recipient must either:
    • 6.1. Use Promega HaloTag® ligands, which can be modified or linked to Promega or customer-supplied moieties; or
    • 6.2. Contact Promega to obtain a license if Promega HaloTag® ligands are not to be used.
  • 7. Disclaimer and Governing Law:
    • 7.1. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE MATERIAL. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.

What's in the box?

Item Part # Size

TLR7 Effector Cells

CS3633B03 5 × 0.5ml

Fetal Bovine Serum

J121A 5 × 4ml

DMEM with 4.5g/L Glucose, L-Glutamine, Sodium Pyruvate

J236A 5 × 60ml

Bio-Glo-NL™ Luciferase Assay Buffer

J308A 5 × 10ml

Bio-Glo-NL™ Luciferase Assay Substrate

J309A 5 × 200μl

Certificate of Analysis

Search by lot number

Patents and Disclaimers

Promega Cell Line Limited Use Label License (LULL)


BY USE OF THIS MATERIAL, RECIPIENT AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE.


  • 1. Usage and Transfer Restrictions:
    • 1.1. Recipient may use this material for research use only, which includes but is not limited to drug discovery and development, quality assurance testing and product release assays. No transfer, resale or commercial use of this material is allowed without the written consent of Promega Corporation.
    • 1.2. “Commercial use” means any and all uses of this material or derivatives by recipient for monetary or other consideration, including product manufacture, providing a service, information or data to unaffiliated third parties and resale of the material for any use.
  • 2. Modification Restrictions:
    • 2.1. Recipient shall have no right to modify, derivatize or otherwise create variations of the nucleotide sequence of any proprietary gene, including but not limited to luciferase, NanoBiT® technology (e.g., HiBiT), HaloTag® technology or genes stably transfected within the cells.
    • 2.2. Recipient shall have no right to genetically engineer or otherwise modify the cell line.
  • 3. Propagation and Storage:
    • 3.1. The recipient may not propagate the cells, unless material is marked as Propagation Model, Cell Bank or Master Cell Bank; then recipient may propagate and store the cells for long-term use.
  • 4. For all determinations of luminescence or other assay-related activity of this material and its derivatives, recipient must either:
    • 4.1. Use the detection systems specified in the protocol or data report and purchased from Promega for all luminescence assays when using this material; or
    • 4.2. Contact Promega to obtain a license for use of this material with reagents other than a Bio-Glo™ branded luciferase reagent, including but not limited to:
      • 4.2.1 Bio-Glo™, Bio-Glo-NL™, Bio-Glo-NB™ TCK, Bio-Glo-NB™ VLP, Bio-Glo-NB™ Lytic
  • 5. For uses of this material for energy transfer (such as bioluminescence resonance energy transfer), recipient must:
    • 5.1. Use NanoBRET™-branded luminescent assay reagents (LARs; e.g., NanoBRET™ Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine™/Inhibitor for all determinations of luminescent activity by this material and its derivatives; and
    • 5.2. Use NanoBRET™-branded energy acceptors (e.g., NanoBRET™ tracers, NanoBRET™ dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this material and its derivatives; or
    • 5.3. Contact Promega to obtain a license for the use of the material and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
  • 6. For uses of HaloTag® Technology in this material, recipient must either:
    • 6.1. Use Promega HaloTag® ligands, which can be modified or linked to Promega or customer-supplied moieties; or
    • 6.2. Contact Promega to obtain a license if Promega HaloTag® ligands are not to be used.
  • 7. Disclaimer and Governing Law:
    • 7.1. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE MATERIAL. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.

What's in the box?

Item Part # Size

TLR7 Effector Cells (CPM)

CS3633B01 2 × 1ml

Certificate of Analysis

Search by lot number

Storage Conditions

XX

Patents and Disclaimers

Promega Cell Line Limited Use Label License (LULL)


BY USE OF THIS MATERIAL, RECIPIENT AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE.


  • 1. Usage and Transfer Restrictions:
    • 1.1. Recipient may use this material for research use only, which includes but is not limited to drug discovery and development, quality assurance testing and product release assays. No transfer, resale or commercial use of this material is allowed without the written consent of Promega Corporation.
    • 1.2. “Commercial use” means any and all uses of this material or derivatives by recipient for monetary or other consideration, including product manufacture, providing a service, information or data to unaffiliated third parties and resale of the material for any use.
  • 2. Modification Restrictions:
    • 2.1. Recipient shall have no right to modify, derivatize or otherwise create variations of the nucleotide sequence of any proprietary gene, including but not limited to luciferase, NanoBiT® technology (e.g., HiBiT), HaloTag® technology or genes stably transfected within the cells.
    • 2.2. Recipient shall have no right to genetically engineer or otherwise modify the cell line.
  • 3. Propagation and Storage:
    • 3.1. The recipient may not propagate the cells, unless material is marked as Propagation Model, Cell Bank or Master Cell Bank; then recipient may propagate and store the cells for long-term use.
  • 4. For all determinations of luminescence or other assay-related activity of this material and its derivatives, recipient must either:
    • 4.1. Use the detection systems specified in the protocol or data report and purchased from Promega for all luminescence assays when using this material; or
    • 4.2. Contact Promega to obtain a license for use of this material with reagents other than a Bio-Glo™ branded luciferase reagent, including but not limited to:
      • 4.2.1 Bio-Glo™, Bio-Glo-NL™, Bio-Glo-NB™ TCK, Bio-Glo-NB™ VLP, Bio-Glo-NB™ Lytic
  • 5. For uses of this material for energy transfer (such as bioluminescence resonance energy transfer), recipient must:
    • 5.1. Use NanoBRET™-branded luminescent assay reagents (LARs; e.g., NanoBRET™ Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine™/Inhibitor for all determinations of luminescent activity by this material and its derivatives; and
    • 5.2. Use NanoBRET™-branded energy acceptors (e.g., NanoBRET™ tracers, NanoBRET™ dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this material and its derivatives; or
    • 5.3. Contact Promega to obtain a license for the use of the material and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
  • 6. For uses of HaloTag® Technology in this material, recipient must either:
    • 6.1. Use Promega HaloTag® ligands, which can be modified or linked to Promega or customer-supplied moieties; or
    • 6.2. Contact Promega to obtain a license if Promega HaloTag® ligands are not to be used.
  • 7. Disclaimer and Governing Law:
    • 7.1. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE MATERIAL. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.

What's in the box?

Item Part # Size

TLR8 Effector Cells

CS3633B10 1 × 0.5ml

Fetal Bovine Serum

J121A 1 × 4ml

DMEM with 4.5g/L Glucose, L-Glutamine, Sodium Pyruvate

J236A 1 × 60ml

Bio-Glo-NL™ Luciferase Assay Buffer

J308A 1 × 10ml

Bio-Glo-NL™ Luciferase Assay Substrate

J309A 1 × 200μl

Certificate of Analysis

Search by lot number

Patents and Disclaimers

Promega Cell Line Limited Use Label License (LULL)


BY USE OF THIS MATERIAL, RECIPIENT AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE.


  • 1. Usage and Transfer Restrictions:
    • 1.1. Recipient may use this material for research use only, which includes but is not limited to drug discovery and development, quality assurance testing and product release assays. No transfer, resale or commercial use of this material is allowed without the written consent of Promega Corporation.
    • 1.2. “Commercial use” means any and all uses of this material or derivatives by recipient for monetary or other consideration, including product manufacture, providing a service, information or data to unaffiliated third parties and resale of the material for any use.
  • 2. Modification Restrictions:
    • 2.1. Recipient shall have no right to modify, derivatize or otherwise create variations of the nucleotide sequence of any proprietary gene, including but not limited to luciferase, NanoBiT® technology (e.g., HiBiT), HaloTag® technology or genes stably transfected within the cells.
    • 2.2. Recipient shall have no right to genetically engineer or otherwise modify the cell line.
  • 3. Propagation and Storage:
    • 3.1. The recipient may not propagate the cells, unless material is marked as Propagation Model, Cell Bank or Master Cell Bank; then recipient may propagate and store the cells for long-term use.
  • 4. For all determinations of luminescence or other assay-related activity of this material and its derivatives, recipient must either:
    • 4.1. Use the detection systems specified in the protocol or data report and purchased from Promega for all luminescence assays when using this material; or
    • 4.2. Contact Promega to obtain a license for use of this material with reagents other than a Bio-Glo™ branded luciferase reagent, including but not limited to:
      • 4.2.1 Bio-Glo™, Bio-Glo-NL™, Bio-Glo-NB™ TCK, Bio-Glo-NB™ VLP, Bio-Glo-NB™ Lytic
  • 5. For uses of this material for energy transfer (such as bioluminescence resonance energy transfer), recipient must:
    • 5.1. Use NanoBRET™-branded luminescent assay reagents (LARs; e.g., NanoBRET™ Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine™/Inhibitor for all determinations of luminescent activity by this material and its derivatives; and
    • 5.2. Use NanoBRET™-branded energy acceptors (e.g., NanoBRET™ tracers, NanoBRET™ dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this material and its derivatives; or
    • 5.3. Contact Promega to obtain a license for the use of the material and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
  • 6. For uses of HaloTag® Technology in this material, recipient must either:
    • 6.1. Use Promega HaloTag® ligands, which can be modified or linked to Promega or customer-supplied moieties; or
    • 6.2. Contact Promega to obtain a license if Promega HaloTag® ligands are not to be used.
  • 7. Disclaimer and Governing Law:
    • 7.1. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE MATERIAL. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.

What's in the box?

Item Part # Size

TLR8 Effector Cells

CS3633B10 5 × 0.5ml

Fetal Bovine Serum

J121A 5 × 4ml

DMEM with 4.5g/L Glucose, L-Glutamine, Sodium Pyruvate

J236A 5 × 60ml

Bio-Glo-NL™ Luciferase Assay Buffer

J308A 5 × 10ml

Bio-Glo-NL™ Luciferase Assay Substrate

J309A 5 × 200μl

Certificate of Analysis

Search by lot number

Patents and Disclaimers

Promega Cell Line Limited Use Label License (LULL)


BY USE OF THIS MATERIAL, RECIPIENT AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE.


  • 1. Usage and Transfer Restrictions:
    • 1.1. Recipient may use this material for research use only, which includes but is not limited to drug discovery and development, quality assurance testing and product release assays. No transfer, resale or commercial use of this material is allowed without the written consent of Promega Corporation.
    • 1.2. “Commercial use” means any and all uses of this material or derivatives by recipient for monetary or other consideration, including product manufacture, providing a service, information or data to unaffiliated third parties and resale of the material for any use.
  • 2. Modification Restrictions:
    • 2.1. Recipient shall have no right to modify, derivatize or otherwise create variations of the nucleotide sequence of any proprietary gene, including but not limited to luciferase, NanoBiT® technology (e.g., HiBiT), HaloTag® technology or genes stably transfected within the cells.
    • 2.2. Recipient shall have no right to genetically engineer or otherwise modify the cell line.
  • 3. Propagation and Storage:
    • 3.1. The recipient may not propagate the cells, unless material is marked as Propagation Model, Cell Bank or Master Cell Bank; then recipient may propagate and store the cells for long-term use.
  • 4. For all determinations of luminescence or other assay-related activity of this material and its derivatives, recipient must either:
    • 4.1. Use the detection systems specified in the protocol or data report and purchased from Promega for all luminescence assays when using this material; or
    • 4.2. Contact Promega to obtain a license for use of this material with reagents other than a Bio-Glo™ branded luciferase reagent, including but not limited to:
      • 4.2.1 Bio-Glo™, Bio-Glo-NL™, Bio-Glo-NB™ TCK, Bio-Glo-NB™ VLP, Bio-Glo-NB™ Lytic
  • 5. For uses of this material for energy transfer (such as bioluminescence resonance energy transfer), recipient must:
    • 5.1. Use NanoBRET™-branded luminescent assay reagents (LARs; e.g., NanoBRET™ Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine™/Inhibitor for all determinations of luminescent activity by this material and its derivatives; and
    • 5.2. Use NanoBRET™-branded energy acceptors (e.g., NanoBRET™ tracers, NanoBRET™ dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this material and its derivatives; or
    • 5.3. Contact Promega to obtain a license for the use of the material and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
  • 6. For uses of HaloTag® Technology in this material, recipient must either:
    • 6.1. Use Promega HaloTag® ligands, which can be modified or linked to Promega or customer-supplied moieties; or
    • 6.2. Contact Promega to obtain a license if Promega HaloTag® ligands are not to be used.
  • 7. Disclaimer and Governing Law:
    • 7.1. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE MATERIAL. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.

What's in the box?

Item Part # Size

TLR8 Effector Cells (CPM)

CS3633B08 2 × 1ml

Certificate of Analysis

Search by lot number

Storage Conditions

XX

Patents and Disclaimers

Promega Cell Line Limited Use Label License (LULL)


BY USE OF THIS MATERIAL, RECIPIENT AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE.


  • 1. Usage and Transfer Restrictions:
    • 1.1. Recipient may use this material for research use only, which includes but is not limited to drug discovery and development, quality assurance testing and product release assays. No transfer, resale or commercial use of this material is allowed without the written consent of Promega Corporation.
    • 1.2. “Commercial use” means any and all uses of this material or derivatives by recipient for monetary or other consideration, including product manufacture, providing a service, information or data to unaffiliated third parties and resale of the material for any use.
  • 2. Modification Restrictions:
    • 2.1. Recipient shall have no right to modify, derivatize or otherwise create variations of the nucleotide sequence of any proprietary gene, including but not limited to luciferase, NanoBiT® technology (e.g., HiBiT), HaloTag® technology or genes stably transfected within the cells.
    • 2.2. Recipient shall have no right to genetically engineer or otherwise modify the cell line.
  • 3. Propagation and Storage:
    • 3.1. The recipient may not propagate the cells, unless material is marked as Propagation Model, Cell Bank or Master Cell Bank; then recipient may propagate and store the cells for long-term use.
  • 4. For all determinations of luminescence or other assay-related activity of this material and its derivatives, recipient must either:
    • 4.1. Use the detection systems specified in the protocol or data report and purchased from Promega for all luminescence assays when using this material; or
    • 4.2. Contact Promega to obtain a license for use of this material with reagents other than a Bio-Glo™ branded luciferase reagent, including but not limited to:
      • 4.2.1 Bio-Glo™, Bio-Glo-NL™, Bio-Glo-NB™ TCK, Bio-Glo-NB™ VLP, Bio-Glo-NB™ Lytic
  • 5. For uses of this material for energy transfer (such as bioluminescence resonance energy transfer), recipient must:
    • 5.1. Use NanoBRET™-branded luminescent assay reagents (LARs; e.g., NanoBRET™ Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine™/Inhibitor for all determinations of luminescent activity by this material and its derivatives; and
    • 5.2. Use NanoBRET™-branded energy acceptors (e.g., NanoBRET™ tracers, NanoBRET™ dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this material and its derivatives; or
    • 5.3. Contact Promega to obtain a license for the use of the material and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
  • 6. For uses of HaloTag® Technology in this material, recipient must either:
    • 6.1. Use Promega HaloTag® ligands, which can be modified or linked to Promega or customer-supplied moieties; or
    • 6.2. Contact Promega to obtain a license if Promega HaloTag® ligands are not to be used.
  • 7. Disclaimer and Governing Law:
    • 7.1. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE MATERIAL. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.

Resources

No related resources available