We believe this site might serve you best:

United States

United States

Language: English

Promega's Cookie Policy

Our website uses functional cookies that do not collect any personal information or track your browsing activity. When you select your country, you agree that we can place these functional cookies on your device.

Our website does not fully support your browser.

We've detected that you are using an older version of Internet Explorer. Your commerce experience may be limited. Please update your browser to Internet Explorer 11 or above.

Wizard® SV Gel and PCR Clean-Up System

Purifies DNA Fragments from Gels or PCR in 15 Minutes

  • Choice of spin- or vacuum-based protocols
  • Purifies 100bp to 10kb DNA fragments

Size

Additional options

Catalog number selected: A9281

$ 103.00
Your price:
Add to Cart
This product is discontinued
Add to Helix
Wizard® SV Gel and PCR Clean-Up System
50 preps
$ 103.00
Your price: Log in
Change Configuration

The Wizard® SV Gel and PCR Clean-Up System is designed to extract and purify DNA fragments of 100bp to 10kb from standard or low-melting agarose gels or to purify products directly from PCR and other common reactions such as restriction digests. PCR products are commonly purified to remove excess nucleotides and primers. 

Up to 95% recovery is achieved depending upon the DNA fragment size, and purified DNA can be eluted in as little as 15μl. This membrane-based system can bind up to 40μg of DNA, and allows recovery of isolated DNA fragments or PCR products in as little as 15 minutes, depending on the number of samples processed. The purified DNA can be used for automated fluorescent DNA sequencing, cloning, labeling, restriction enzyme digestion or in vitro transcription/translation without further manipulation. Purified DNA routinely achieves 700 bases with >98% accuracy in automated fluorescent sequencing.

The x-tracta™ Gel Extractor tool (supplied with Cat.# A9283 and A9284) provides a convenient, safe method for removal of agarose gel fragments for further processing. The device removes a 0.13 × 0.33 inch gel piece from agarose gels for easy transfer into a microcentrifuge tube for processing.

Vacuum Adapters (Cat.# A1331) are required for use of the vacuum format with the Wizard® SV Gel and PCR Clean-Up System and must be purchased separately.

Specifications

You are viewing: A9281 Change Configuration

What's in the box?

Item Part # SizeAvailable Separately

Wizard® SV Minicolumns

A129A 1 × 50/pk

Collection Tubes

A130A 1 × 50/pk

Membrane Wash Solution

A929B 1 × 15ml

Membrane Binding Solution

A930B 1 × 20ml View Product

Nuclease-Free Water

P119A 3 × 1,250μl View Product

SDS

Choose language:

Download SDSPDF (356 KB) – English (United States)

Certificate of Analysis

See all certificates for A9281

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

DD

Specifications

You are viewing: A9282 Change Configuration

What's in the box?

Item Part # SizeAvailable Separately

Wizard® SV Minicolumns

A129B 1 × 250/pk

Collection Tubes

A130B 1 × 250/pk

Membrane Wash Solution

A929C 1 × 75ml

Membrane Binding Solution

A9303 1 × 100ml View Product

Nuclease-Free Water

P119E 1 × 13ml View Product

SDS

Choose language:

Download SDSPDF (344 KB) – English (United States)

Certificate of Analysis

See all certificates for A9282

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

DD

Specifications

You are viewing: A9285 Change Configuration

What's in the box?

Item Part # SizeAvailable Separately

Wizard® SV Minicolumns

A129B 4 × 250/pk

Collection Tubes

A130B 4 × 250/pk

Membrane Wash Solution

A929C 4 × 75ml

Membrane Binding Solution

A9303 4 × 100ml View Product

Nuclease-Free Water

P119E 4 × 13ml View Product

SDS

Choose language:

Download SDSPDF (264 KB) – English (United States)

Certificate of Analysis

See all certificates for A9285

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

DD

Specifications

You are viewing: A9283 Change Configuration

What's in the box?

Item Part # SizeAvailable Separately

Wizard® SV Minicolumns

A129A 1 × 50/pk

Collection Tubes

A130A 1 × 50/pk

Membrane Wash Solution

A929B 1 × 15ml

Membrane Binding Solution

A930B 1 × 20ml View Product

Nuclease-Free Water

P119A 3 × 1,250μl View Product

x-tracta™ Gel Extractor

A2121 1 × 25/pack

SDS

Choose language:

Download SDSPDF (276 KB) – English (United States)

Certificate of Analysis

See all certificates for A9283

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

DD

Specifications

You are viewing: A9284 Change Configuration

What's in the box?

Item Part # SizeAvailable Separately

Wizard® SV Minicolumns

A129B 1 × 250/pk

Collection Tubes

A130B 1 × 250/pk

Membrane Wash Solution

A929C 1 × 75ml

Membrane Binding Solution

A9303 1 × 100ml View Product

Nuclease-Free Water

P119E 1 × 13ml View Product

x-tracta™ Gel Extractor

A2122 1 × 100/pack

SDS

Choose language:

Download SDSPDF (345 KB) – English (United States)

Certificate of Analysis

See all certificates for A9284

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

DD

Let's find the product that meets your needs.

Talk to a Scientist

Maria

Maria

Spain