Designing a Bioluminescent Reporter Assay - Choosing Your Experimental Reporter

 

What makes a good reporter assay?

When it comes to designing a good reporter assay there are a number of parameters to consider: What cells should I work in? How will I introduce my reporter into my cells? How should I design my reporter construct? What controls should I use? Two of the fundamental elements you need to consider are the reporter protein itself and the assay chemistry used to detect reporter activity. Attributes of these two components together contribute strongly to the quality of the assay.

We use three luciferases as reporters in our bioluminescent assays: NanoLuc® Luciferase (19kDa), Renilla Luciferase (36kDa) and Firefly Luciferase (61kDa). Including the destabilized versions of Firefly and NanoLuc® Luciferases, we offer 5 different bioluminescent reporters and multiple detection assays for each. So, how do you choose the combination that is right for you? First, let's look at the reporter characteristics.

Ideal Characteristics of Reporter Assay Components

Reporter Protein:

  • enzymatic activity (signal amplification)
  • small
  • no processing to be active
  • monomer

Reporter Assay Chemistry:

  • low background
  • easy to use and measure
  • quantitative
  • sensitive, broad dynamic range

Signal Strength

NanoLuc® Luciferase provides the brightest signal. On a per mole basis, NanoLuc® Luciferase is approximately 100-fold brighter than Firefly or Renilla Luciferase. This difference in brightness can be seen in cells as well, and makes NanoLuc®-based assays more sensitive than those using other luciferases.

Response Time

NanoLuc (Nluc) and Firefly (luc2) Luciferases have destabilized versions (NlucP and luc2P) that contain the PEST protein degradation sequence, targeting them for rapid degradation. The PEST sequence drastically reduces the half-life of the enzyme. A destabilized reporter will have a smaller intracellular pool of protein allowing for a faster, more sensitive response to changes in expression.

Half-life varies between Nluc and Fluc reporters as follows:

  • NlucP - 20 minutes
  • Fuc2P - 1 hour
  • Fluc2 - 3 hours
  • Nluc - 6 hours

In the experiment shown on the right, constructs using an NFkB promoter and either a NlucP, FlucP, Nluc or Fluc reporter gene were used to transfect HEK293 cells. Cells were treated at time 0 with TNFalpha, which induces expression from the NFkB promoter. The fastest and strongest response was from the NlucP construct followed by the FlucP construct.

Sensitivity for Weak Responses

The previous experiment measured a strong response to a stimulus. Many physiological responses are more subtle. How would these four reporters perform in an assay measuring a weaker response? The experiment on the right shows that NlucP is the best choice when sensitivity is an issue. In these experiments, the heat-shock response element (HSE) was used to drive expression of each reporter. Treatment of the cells with the heat-shock mimetic, 17-AAG [17-(allylamino)-17-demethoxygeldanamycin), activates the hsf1 transcription factor which in turn activates the HSE. The NlucP reporter construct is the only one that demonstrates a significant response above background.

Choosing an Assay

Choosing a detection assay depends on several factors. As shown earlier, your choice of reporter will affect signal strength, response time and sensitivity. If you choose Nluc or NlucP as your reporter, you will detect activity with the Nano-Glo Luciferase Assay System, which provides stable, glow-type signal in the presence of Nluc, with a half-life of approximately 120 minutes.

In many cases, firefly luciferase is still a very good reporter option and many constructs exist using Fluc and FlucP as the reporter. There are multiple assay chemistry options for detection of the Fluc reporter allowing you to choose the detection assay most appropriate for your particular experimental needs. Assays for detection of firefly luciferase include options with either “flash” or “glow” signal kinetics. A “flash” assay is one where the signal is strong but short-lived requiring injection-based delivery of reagent. In contrast, a “Glow” type assay has a prolonged signal eliminating the need for injectors, but with generally lower signal intensities. Learn more about “flash vs glow”. The figure on the right compares signal strength and duration using different firefly assays with glow signal kinetics. The Bright-Glo™ Assay provides the brightest signal, but it decays rapidly. On the other hand, the Steady-Glo® Assay provides the most consistent signal duration with the lowest intensity. The ONE-Glo™ and ONE-Glo™ EX assays are ideally suited for high-throughput use. The ONE-Glo™ EX Reagent has the added advantage of improved stability, allowing you to make up the reagent and store it at 4⁰C for several weeks, simplifying repeat use if you have a set of experiments to run.

What about dual-reporter assays?

Dual-reporter assays are an excellent way to control for variations in your results or maximize your data. Firefly and Renilla luciferases can be used together with the Dual-Luciferase (flash kinetics) or Dual-Glo (stable kinetics) Assay Systems. The choice largely depends on the sensitivity and signal stability required for your experiment. Alternatively, firefly and NanoLuc luciferases can be combined in the Nano-Glo Dual-Luciferase Reporter Assay (NanoDLR) for improved sensitivity in dual-reporter assay with stable signal kinetics.

Next: Read "Designing a Bioluminescent Reporter Assay: Normalization"