CytoTox-ONE™ Homogeneous Membrane Integrity Assay
The CytoTox-ONE™ Homogeneous Membrane Integrity Assay is a fluorometric method for estimating the number of nonviable cells present in multiwell plates. The assay rapidly measures the release of lactate dehydrogenase (LDH) from cells with a damaged membrane. LDH released into the culture medium is measured with a 10-minute coupled enzymatic assay that results in the conversion of resazurin into a fluorescent resorufin product. The amount of fluorescence produced is proportional to the number of lysed cells using a 96- or 384-well format. The CytoTox-ONE™ Reagent does not damage normal healthy cells; therefore the reactions set up to measure released LDH can be performed directly in a homogeneous format in assay wells containing a mixed population of viable and damaged cells.
The CytoTox-ONE™ Homogeneous Membrane Integrity Assay, HTP (Cat.# G7892), offers convenient, alternative packaging for processing multiple plates. Each bottle of reagent supplied with the system is sufficient to perform 500 assays in a 96-well format or 2,000 assays in a 384-well format when the recommended volumes are used.
Save time by setting up the assay in a cell culture plate; this eliminates the sample transfer step common in many LDH assays. Plates are then incubated for just 10 minutes before reading data, compared to 30 minutes or more with classic LDH assays.
Multiplexing capability allows you to perform multiple assays on one sample with other homogeneous cell-based assays from Promega.
Adapt the assay protocol to your needs; completed assays can be read over several hours after the provided stop solution has been added while still maintaining good signal.
Protocols
Specifications
Catalog Number:
Contenido
| Item | Part # | Presentación |
|---|---|---|
|
Substrate Mix |
G179A | 2 × 1 vial |
|
Lysis Solution |
G182B | 1 × 0.5ml |
|
Assay Buffer |
G790A | 1 × 24ml |
|
Stop Solution |
G791A | 1 × 11ml |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
Contenido
| Item | Part # | Presentación |
|---|---|---|
|
Substrate Mix |
G179A | 10 × 1 vial |
|
Lysis Solution |
G182B | 1 × 0.5ml |
|
Assay Buffer |
G790B | 1 × 120ml |
|
Stop Solution |
G791B | 1 × 60ml |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
Contenido
| Item | Part # | Presentación |
|---|---|---|
|
Substrate Mix |
G179B | 2 × 1 vial |
|
Lysis Solution |
G182B | 1 × 0.5ml |
|
Assay Buffer |
G790B | 1 × 120ml |
|
Stop Solution |
G791B | 1 × 60ml |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
Resources
No related resources available
Related Products
Productos Similares
LDH-Glo™ Cytotoxicity Assay
Ensayo LDH basado en bioluminiscencia para detectar de forma sensible la citotoxicidad en muestras con bajo número de células, incluidos los microtejidos 3D.
J2380, J2381
CytoTox-Glo™ Cytotoxicity Assay
Ensayo de citotoxicidad basado en luminiscencia, de alta sensibilidad que mide el número relativo de células muertas.
G9290, G9291, G9292
CytoTox-Fluor™ Cytotoxicity Assay
Ensayo fluorescente homogéneo de adición de un solo reactivo, que le permite medir el número relativo de células muertas en poblaciones celulares.
G9260, G9261, G9262
CellTox™ Green Cytotoxicity Assay
Mide los cambios en la integridad de la membrana. Monitoriza cinéticamente la citotoxicidad hasta 72 horas y además tiene capacidad multiplex.
G8741, G8742, G8743, G8731
Usado con frecuencia junto con
Caspase-Glo® 9 Assay Systems
Mida la actividad de la caspasa-9 con este ensayo luminiscente homogéneo.
G8210, G8211, G8212
Caspase-Glo® 8 Assay Systems
Mida la actividad de la caspasa-8 con este ensayo luminiscente homogéneo.
G8200, G8201, G8202
CellTiter-Blue® Cell Viability Assay
Ensayo fluorescente, homogéneo y con resazurina que permite monitorizar la viabilidad celular.
G8080, G8081, G8082
CellTiter-Glo® Luminescent Cell Viability Assay
Determine el número de células viables en el cultivo a partir de la cuantificación del ATP presente.
G7570, G7571, G7572, G7573