Accessory Products
| Catalog No. | Product Name | Size | Price | Qty | |||
|---|---|---|---|---|---|---|---|
| E6531 | GloMax® Luminometer Light Plate | View Specifications | 1 each | Consultar Precio | |||
| GM1090 | GloMax® Discover Standard Luminescence Paddle with Filters | View Specifications | 1 each | Consultar Precio | |||
| GM3012 | GloMax® Discover Fluorescence Filter Paddle | View Specifications | 1 each | Consultar Precio | |||
| GM1100 | GloMax® Discover/Explorer Standard Fluor Paddle w/Filters | View Specifications | 1 each | Consultar Precio | |||
| GM1050 | GloMax® Discover 96 Half-Position Aperture Assembly | View Specifications | 1 each | Consultar Precio | |||
| GM3520 | GloMax® Explorer Absorbance Module Upgrade | View Specifications | 1 each | Consultar Precio | |||
| GM3560 | GloMax® Explorer UV-Visible Absorbance Module Upgrade | View Specifications | 1 each | Consultar Precio | |||
| GM3570 | GloMax® Explorer BRET/FRET Upgrade | View Specifications | 1 each | Consultar Precio | |||
| GM3030 | GloMax® Dual Injectors with Pumps | View Specifications | 1 each | Consultar Precio | |||
| GM3014 | Inner and Outer Injector Tubing, Natural | View Specifications | 1 each | Consultar Precio | |||
| AS8403 | USB Ethernet Adapter | View Specifications | 1 each | Consultar Precio | |||
| AS3200 | Maxwell® Instrument Bar Code Reader | View Specifications | 1 each | Consultar Precio | |||
| GM3042 | GloMax® Discover Aperture Change Base Assembly | View Specifications | 1 each | Consultar Precio |
Early Access = This product is available under our Early Access program - Learn More
Catalog (FT) = This product is available under our Catalog (FT) program - Learn More
Other Products
| Catalog No. | Product Name | Size | Price | Qty | |||
|---|---|---|---|---|---|---|---|
| GM3011 | GloMax® Discover Luminescence Filter Paddle | View Specifications | 1 each | Consultar Precio | |||
| GM3040 | GloMax® Discover 96-Position Aperture Assembly | View Specifications | 1 each | Consultar Precio | |||
| GM3041 | GloMax® Discover 384-Position Aperture Assembly | View Specifications | 1 each | Consultar Precio |
Early Access = This product is available under our Early Access program - Learn More
Catalog (FT) = This product is available under our Catalog (FT) program - Learn More
Dual Injectors with Pumps
Dual Injectors with Pump Station
Injector System console with vertical support rods, Inlet Tubing Assembly, Inlet Tubing Holder, Waste Collection Tray, Outlet Tubing Assembly and DB-15 Data Cable.
Tubing inside the GloMax® Discover and Explorer instruments are pre-installed for easy and quick connection to the Dual Injectors with Pump Station.
Specifications
Number of injectors: 2 injectors
Dispense volume range: 5–200µl in 1µl increments
Plate compatibility: 6-, 12-, 24-, 48- and 96-well plates
Waste collection tray volume: approximately 50ml
Void volume: 600µl
For use with GloMax® Discover and GloMax® Explorer.
Bar Code Reader
Bar Code Reader
Bar Code Reader with USB connection cable.
Inner and Outer Injector Tubing Set
Replacement Injector Tubing Set
Replacement inner and outer injector tubing set for use with GM3030, GloMax® Dual Injector with Pumps.
Color: Natural
For use with GloMax® Discover and GloMax® Explorer.
USB Ethernet Adapter
USB Driver to Connect GloMax® Instruments to an External PC
The USB Ethernet Adapter is used to connect GloMax® Instruments to an external PC for data transfer, or to operate the instruments via the PC. If the computer is not connected to the internet, or you wish to manually download the latest drivers they can be found on the Future Technology Devices International Limited (FTDI) website.
- Locate the “Currently Supported D2XX Driver table” from the FTDI website.
- Locate the Windows® operating system details in the table.
- In the far right column select the “Setup Executable”, which will automatically install the appropriate drivers to the PC.
- The message “Found New Hardware” message will still launch when the instrument is plugged into a USB port for the first time, but Windows® should automatically use these latest drivers during the installation.
Tripp-Lite USB to RS-232 Serial Adapter Driver
As an alternative to a USB cable, an RS-232 cable can be used to connect the instrument to a PC. With this method, PCs that do not have a built in RS-232 port will require a Serial to USB adapter. We recommend the Tripp-Lite USB to Serial Adapter (U209-000-R). The drivers for the adapter are included on the CD supplied with the adapter. Alternatively, the drivers for the adapter can also be found on the Tripp-Lite website.
Fluorescence Filter Paddle
Replacement Fluorescence Filter Paddle
Replacement Filter paddle containing fluorescence emission filters. Empty filter positions are available for custom emission wavelengths. Contact Promega Technical Services.
GloMax® Discover and GloMax® Explorer Systems come pre-installed with this Fluorescence Filter Paddle, configured for a wide variety of fluorescent assays.
For use with GloMax® Discover and GloMax® Explorer.
Empty Fluorescence Filter Paddle
Empty Filter Paddle
Six (6)-position filter paddle for user-defined emission filters for fluorescence applications.
For use with GloMax® Discover and GloMax® Explorer.
Luminescence Filter Paddle
Replacement Luminescence Filter Paddle
Replacement filter paddle containing emission filters for filtered luminescence including NanoBRET® and other BRET assays. Includes: 495nm SP, 530nm LP, 540nm SP, 600nm LP and 450nm (8nm BP). Additional custom emission filters may also be used. Contact Promega Technical Services.
GloMax® Discover System comes pre-installed with this Luminescence Filter Paddle, configured for NanoBRET® and other BRET assays.
Note: Glo, Flash and Kinetic luminescence assays do not require the use of filters. Filters are only used for filtered luminescence assays, such as BRET.
For use with GloMax® Discover only.
Empty Luminescence Filter Paddle
Empty Filter Paddle
Five (5)-position filter paddle for user-defined emission filters for filtered luminescence applications.
Note: Glo, Flash and Kinetic luminescence assays do not require the use of filters. Filters are only used for filtered luminescence assays, such as BRET.
For use with GloMax® Discover only.
Light Plate
Microplate Luminometer Light Plate
The Microplate Luminometer Light Plate provides a quick and easy way to verify the performance of our Microplate Luminometers. It allows you to check the reproducibility, sensitivity and linearity of the luminometer. It can be used for both short- and long-term stability studies of the detection system.
Specifications
Dimensions: 5'' × 3.36'' × 0.57''
Weight: 9oz
Spectral range of light emission: 565±10nm
Dynamic Range: 4 decades
Power: One 6V 500 mAH 539 J-type battery
Operation duration: >400 measurements
Operating temperature: 20–350°C
Storage temperature: 10–40°C
Humidity: 5–75%
96-Well Aperture
Replacement 96-Well Aperture Assembly
Internal mask used to reduce cross talk from neighboring wells when measuring samples in 6-, 12-, 24-, 48- and 96-well microplates.
Pre-installed with GloMax® Discover and GloMax® Explorer Systems.
384-Well Aperture
Replacement 384-Well Aperture Assembly
Internal mask used to reduce cross talk from neighboring wells when measuring samples in 384-well microplates.
Pre-installed with GloMax® Discover and GloMax® Explorer Systems.
Aperture Plate
Aperture Plate Assembly Baffle Exchange
Used to install the Aperture Assembly.
Included with GloMax® Discover and GloMax® Explorer Systems.
96-Well Half-Area Aperture
96-Well Half-Area Aperture Assembly
Internal mask used to reduce cross talk from neighboring wells when measuring samples in Half-Area 96-well microplates.
For use with GloMax® Discover and GloMax® Explorer.
Protocols
No protocols available
Specifications
Catalog Number:
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
Resources
No related resources found