The PDE-Glo™ Phosphodiesterase Assay is a luminescent, high-throughput screening (HTS) method for measuring cyclic nucleotide phosphodiesterase (PDE) activity from purified sources.
Cyclic nucleotide phosphodiesterases are involved in many cellular processes due to their ability to hydrolyze, and thus control, the levels of the second-messenger signaling molecules cAMP and cGMP.
The availability of selective inhibitors for PDEs has facilitated their use as tools to study cyclic nucleotide signaling and paved the way to investigate the role of PDEs in cellular and tissue pathologies. The PDE-Glo™ Assay is used for screening library compounds to identify inhibitors of either cAMP- or cGMP-specific PDEs. The assay is designed for 384-well plates, but volumes can easily be scaled for 96- or 1536-well plates. The PDE-Glo™ Phosphodiesterase Assay is optimized to work with both cAMP- and cGMP-dependent phosphodiesterases. The total time required for the assay from start to finish is less than 1 hour after the PDE reaction is complete.
Assay Advantages
- Test any PDE: Works with both cAMP and cGMP PDEs.
- Detect activity easily: No interference from fluorescent compounds.
- Measure activity directly: Functional test for enzyme activity performed with a low-cost luminometer.
- Excellent signal:background.
- Scalable to 1536-well formats.
- Homogenous assay is complete in <1 hour.
- Powered by Ultra-Glo™ Recombinant Luciferase.
- No interference by fluorescent compounds.
- Non-radioactive.
Protocols
Specifications
Catalog Number:
Contenido
| Item | Part # | Presentación |
|---|---|---|
|
PDE-Glo™ Reaction Buffer 5X |
V133A | 1 × 1.2ml |
|
PDE-Glo™ Detection Buffer 5X |
V134A | 1 × 600μl |
|
Protein Kinase A |
V135A | 1 × 20μl |
|
PDE-Glo™ Termination Buffer 5X |
V136A | 1 × 600μl |
|
cGMP, 1mM |
V641A | 1 × 500μl |
|
cAMP, 1mM |
V642B | 1 × 100μl |
|
Kinase-Glo® Substrate |
V672A | 1 × 1 vial |
|
Kinase-Glo® Buffer |
V673A | 1 × 10ml |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
Store at –20°C.
Resources
No related resources available
Related Products
Productos Similares
cAMP-Glo™ Max Assay
Ensayo de alto rendimiento de 30 minutos para medir AMPc en células.
V1681, V1682, V1683
GloSensor™ Technology
Biosensores de células vivas para AMPc, GMPc o actividad de proteasas.
E1290, E1291, E2301, E1171
cAMP
Activador de la subunidad catalítica de la proteína quinasa dependiente de AMPc.
V6421
cGMP
Activador de la proteína quinasa dependiente de GMPc.
V6411
Usado con frecuencia junto con
GloMax® Explorer System
Sistema de detección multimodo, flexible y fácil de usar.
GM3500, GM3510
GloMax® Navigator System
Luminómetro para microplacas.
GM2000, GM2010
GloMax® Discover System
Lector de microplacas de alto rendimiento para la detección de luminiscencia, fluorescencia y absorbancia.
GM3000