Lumit® IL-10 (Human) Immunoassay
No-Wash Immunoassay for IL-10 Detection
- Fast add-and-read protocol performed directly on cells
- Luminescent detection with just a plate-reading luminometer
- Scalable to 96- or 384- well plates, protocols included
- Pack sizes show assay number for 96-well plates
Catalog Number:
Choose a product
Size
Catalog Number: W6070
Catalog Number: W6072
Catalog Number: W6071
Catalog Number: W131A-C
Quantify Cytokine Release Without Tedious Wash Steps
The Lumit® IL-10 Immunoassay quantitatively measures released IL-10 in cell culture samples using a simple, no-wash protocol. Just add labeled antibodies to the sample, add detection reagent and read luminescent signal using a standard plate-reading luminometer. The entire protocol is completed in less than 70 minutes! The assay can be used directly on cells in culture or culture medium transferred to a separate assay plate.
Note: The total number of assays per kit will vary based on final well volume.
For standard well volumes:
- 100 assay kits: applicable for 100 assays in 96-well plates or 400 assays in 384-well plates.
- 500 assay kits: applicable for 500 assays in 96-well plates or 2,000 assays in 384-well plates.
- 1,000 assay kits: applicable for 1,000 assays in 96-well plates or 4,000 assays in 384-well plates.
How the Lumit® IL-10 Immunoassay Works
Primary antibodies to IL-10 were selected for their specific and sensitive detection and labeled with the LgBiT and SmBiT subunits of NanoBiT® Luciferase. In the presence of IL-10, the subunits are brought together to form an active luciferase enzyme. Addition of optimized substrate generates a bright luminescent signal proportional to IL-10 levels.
Simple One-Plate Protocol, No Wash Steps
Large Dynamic Range of Lumit® IL-10 Detection
The pg/ml to ng/ml linear range of Lumit® detection covers expected concentrations for most cell models.
|
Assay |
IL-10 Human Immunoassay |
|
|
Limit of Detection (LOD) |
7.4pg/ml (3 SD above background) |
|
|
Dynamic Range |
18.2pg/ml – 25ng/ml |
|
|
Minimal Detectable Dose (MDD) |
4.9pg/ml (2 SD above background) |
|
|
Assay Time |
70 minutes |
|
|
Sample Type |
Cell culture supernatants |
|
SD=Standard Deviation
IL-10 Release from PBMCs
Human PBMCs were plated in 96-well plate format at 100,000 cells/well and treated with increasing concentrations of lipopolysaccharide (LPS). Following treatment, IL-10 release was quantified with the Lumit® IL-10 (Human) Immunoassay.
Explore Additional Cytokine Detection Assays
We offer a growing portfolio of assays to detect cytokines in cell culture samples.
Can’t find your target in the list?
Please enquire about early access to new assays in development.
For a biotech that understands time is of significant value, the Lumit® Immunoassays are an essential way for us to gather reliable data fast so that we can reach conclusions and make decisions sooner.
Jonathan Chow, Principal Scientist, Corner Therapeutics
Protocols
Complete Protocol
Specifications
Catalog Number:
Contenido
| Item | Part # | Presentación | Concentración |
|---|---|---|---|
Lumit® Detection Substrate B |
VB405A | 1 × 160μl | |
Lumit® Detection Buffer B |
VB406A | 1 × 3.2ml | |
Human IL-10 Standard |
W131A | 1 × 25μl | 10μg/ml |
Anti-hIL-10 mAb-SmBiT, 500X |
W132A | 1 × 30μl | |
Anti-hIL-10 mAb-LgBiT, 500X |
W133A | 1 × 30μl |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Contenido
| Item | Part # | Presentación | Concentración |
|---|---|---|---|
Lumit® Detection Substrate B |
VB405A | 5 × 160μl | |
Lumit® Detection Buffer B |
VB406A | 5 × 3.2ml | |
Human IL-10 Standard |
W131A | 1 × 25μl | 10μg/ml |
Anti-hIL-10 mAb-SmBiT, 500X |
W132A | 5 × 30μl | |
Anti-hIL-10 mAb-LgBiT, 500X |
W133A | 5 × 30μl |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Contenido
| Item | Part # | Presentación | Concentración |
|---|---|---|---|
Lumit® Detection Substrate B |
VB405B | 1 × 1.25ml | |
Lumit® Detection Buffer B |
VB406B | 1 × 25ml | |
Human IL-10 Standard |
W131A | 1 × 25μl | 10μg/ml |
Anti-hIL-10 mAb-SmBiT, 500X |
W132B | 1 × 300μl | |
Anti-hIL-10 mAb-LgBiT, 500X |
W133B | 1 × 300μl |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Contenido
| Item | Part # | Presentación | Concentración |
|---|---|---|---|
Human IL-10 Standard |
W131A | 1 × 25μl | 10μg/ml |
SDS
Search for SDSCertificado de Análisis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Condiciones de Almacenaje
Resources
Otros
- Rapid and Sensitive Determination of Cytokine Release from Cells Without Sample Transfer
- Blog Article: Understanding Inflammation: A Faster, Easier Way to Detect Cytokines in Cells
- Blog Article: The Cytokine Storm: Why Some COVID-19 Cases are More Severe
- White Paper: Lumit® Immunoassays: A Rapid and Sensitive Method for Analyte Detection
Related Products
Productos Similares
Lumit® IL-4 (Human) Immunoassay
Mide cuantitativamente la IL-4 liberada en muestras de cultivos celulares mediante un protocolo sencillo y sin lavado.
W6060, W6062, W6061, W125A-C
Lumit® IL-6 (Human) Immunoassay
Mide cuantitativamente la IL-6 liberada en muestras de cultivos celulares mediante un protocolo sencillo y sin lavado.
W6030, W6032, W6031, W128A-C
Lumit® IFN-γ (Human) Immunoassay
Mide cuantitativamente el IFN-γ liberado en muestras de cultivos celulares mediante un protocolo sencillo y sin lavado.
W6040, W6042, W6041, W134A-C
Lumit® TNF-α (Human) Immunoassay
Mide cuantitativamente el TNF-α liberado en muestras de cultivos celulares mediante un protocolo sencillo y sin lavado.
W6050, W6052, W6051, W137A-C
Usado con frecuencia junto con
Thaw-and-Use Primary Effector Cells
Consistent and robust method for target cell killing.
CS3055C02, CS3055C03, CS3055B03, CS3055B06, CS3055A15, CS3055A18
CellTox™ Green Cytotoxicity Assay
Mide los cambios en la integridad de la membrana. Monitoriza cinéticamente la citotoxicidad hasta 72 horas y además tiene capacidad multiplex.
G8741, G8742, G8743, G8731
Lumit® Immunoassay Labeling Kit and Detection Reagents
Kit de marcaje de anticuerpos y reactivos de detección para ayudar a desarrollar inmunoensayos Lumit®.
VB2500, VB2010, VB2020, VB2030, VB4050, VB4060
GloMax® Discover System
Lector de microplacas de alto rendimiento para la detección de luminiscencia, fluorescencia y absorbancia.
GM3000