We believe this site might serve you best:

United States

English Continue

This country code will remain if no action is taken to change it.

Don't see your country?
Promega Corporation

GloMax® Discover: Multimode Detection System

GloMax Header

GloMax® Discover

Experience our integrated detection system.

This ready-to-use multimode detection system includes: high-performance luminescence, fluorescence, UV-Visible absorbance, BRET and FRET, two-color filtered luminescence and kinetic measurement capabilities.

Download GloMax® Systems Brochure

  • Performance & Quality
  • Workflow
  • Specifications
  • Service and Support
 

Performance

The GloMax® Discover System delivers maximum flexibility with minimal user intervention.

Easy-To-Use

  • Choose from preloaded Promega protocols or customize your own.
  • Build custom protocols using the intuitive drag-and-drop interface.
  • Interpret results using integrated data analysis software.
  • Export data to a network, cloud or any drive desired.
EasyToUse
 
MinimalIntervention

Minimal Manual Intervention

  • Filter paddles and automatic filter switching allow easy two-color multiplexing assays or kinetic studies.
  • Quick read-speeds for high efficiencies in your laboratory.
  • Compatible for 3rd party automation control.
 

Superior Sensitivity

  • Plate mask (aperture control) for switching between 96-well and 384-well plates.
  • Low cross-talk between wells gives you better, more usable results.
  • Broad dynamic range of the instrument extends the linear range of your assay.
SuperiorSensitivity
 
Quality

Quality

  • IQ/OQ Service available.
  • Provides many of the required technical elements of a part 11 compliant system (user authentication and authorization, data integrity and protection, electronic signatures and audit trails) when used with the appropriate laboratory workflow.
 
 
Instrument Specifications
Detection Modes Luminescence, Fluorescence Intensity, UV-Visible Absorbance, Filtered Luminescence, BRET and FRET
Sample Format 6, 12, 24, 48, 96 and 384-well plates
Tablet PC Windows®8 Tablet PC with USB connection to instrument
Read Speed 96-well plate: less than 1 minute; 384-well plate: less than 3 minutes
Automation Compatibility Hardware and software accessible to 3rd party hardware/software control, including LIMS.
Integrated Data Analysis Data reduction curve fit software.
Dimensions 18.5in (46.9cm) width
19.5in (46.5cm) depth
10in (25.4cm) height without Tablet and PC mounted
16in (35.5cm) height with Tablet and PC mounted
Weight Approximately 60lbs. (27kg)
Power Requirements 120VA, 50/60 HZ
Warranty 1-year parts and labor warranty included
Regulatory Compliance For Research Use Only. Not for use in Diagnostic Procedures
Luminescence Module Specifications
Detector Top-reading, head-on photon counting photomultiplier tube (PMT)
Wavelength Range 350–700nm
Detection Limit 3 × 10-21 moles of luciferase
Linear Dynamic Range 9 logs
Cross-talk Less than 3 × 10-5 (white, 96-well plate, Corning 3912)
Filtered Luminescence Built-in filter paddle
Fluorescence Module Specifications
Detector PIN-photodiode
Light Source Wavelength-matched LED
Read Position Top reading
Wavelengths selection Filter module with 5 standard excitation and emission filters. Empty filter positions are available for custom excitation and emission wavelengths.
Wavelengths included UV (Ex: 365nm, Em: 415-445nm) Blue (Ex: 475nm, Em: 500-550nm) Green (Ex: 525nm, Em: 580-640nm) Red (Ex: 625nm, Em: 660-720nm) AFC (Ex: 405nm, Em: 495-505nm)
Detection Limit 2fmol fluorescein/200μl
Linear Dynamic Range >6 logs (assay dependent)
UV-Visible Absorbance Module Specifications
Detector Top-reading, head-on photon counting photomultiplier tube (PMT)
Light Source Xenon flash lamp
Spectra Range 200-600nm
Filter Wheel 9 absorbance filters included
Wavelengths included 230, 260, 280, 320, 405, 450, 490, 560 and 600nm 10nm band pass
Detection Limit 0.1 O.D.
Dynamic Range 0-4.0 O.D.
Injector System Specifications
Number of injectors (optional) Two injectors
Dispense Volume Range 5-200μl in 1μl increments
Plate Compatibility 6, 12, 24, 48, and 96-well plates
Injection Speed 20-500μl per second
Waste Collection Tray Volume Approximately 50ml
Void Volume 500μl
Shaker System Specifications
Shaking Pattern Linear or orbital patterns
Shaking Intensity 100-500 cycles/minute
Heating System Specifications
Temperature Range Ambient to 45°C
PC Requirements
Operating System Windows® 8, 64 bit, with USB connection to instrument
RAM 2GB
Disk Space 64GB
Other Requirements Microsoft.NET 4.0 Framework (full version), Microsoft Excel 2013 Professional
 

One Call Supports It All

Promega supplies both the reagents and the instrument, so one call to Promega answers any questions you may have about assay chemistries or instrument performance.

Ensure Minimal Instrument Downtime

  • Field Support and Loaner Programs
  • Service Packages

Warranty and Service Agreements

  • The GloMax® Discover System is backed by a one-year warranty.
  • Additional warranty and service agreements are available.
  • For more information contact Promega Technical Services
Tech Support
 

One Call Supports It All Promega supplies both the reagents and the instrument, so one call to Promega answers any questions you may have about assay chemistries or instrument performance.

Ensure Minimal Instrument Downtime

  • Field Support and Loaner Programs
  • Service Packages

Warranty and Service Agreements

  • The GlomMax® Discover System is backed by a one-year warranty.
  • Additional warranty and service agreements are available.
  • For more information contact Promega Technical Services

It appears that you have Javascript disabled. Our website requires Javascript to function correctly. For the best browsing experience, please enable Javascript.