Abstract for ADP-Glo™ Kinase Assay
Part# TM313
Printed in USA. Revised 8/09.
Instructions for Use of Products V9101,
V9102
& V9103.
The ADP-Glo™ Kinase Assay is a luminescent ADP detection assay that
provides a universal, homogeneous, high-throughput screening method to measure
kinase activity by quantifying the amount of ADP produced during a kinase
reaction. The ADP-Glo™ Kinase Assay can be used to monitor the activity
of virtually any ADP-generating enzyme (e.g., kinase or ATPase) using up to
1mM ATP. The ADP-Glo™ Kinase Assay is performed in a multiwell plate
and can detect kinase activity in a reaction volume as low as 5μl. The
assay is performed in two steps; first, after the kinase reaction, an equal
volume of ADP-Glo™ Reagent is added to terminate the kinase reaction and
deplete the remaining ATP. Second, the Kinase Detection Reagent is added to
simultaneously convert ADP to ATP and allow the newly synthesized ATP to be
measured using a luciferase/luciferin reaction. The light generated is
measured using a luminometer. Luminescence can be correlated to ADP
concentrations by using an ATP-to-ADP conversion curve.
|