Abstract for MagneHis™ Protein Purification System
Part# TM060
Printed in USA. Revised 8/09.
Instructions for Use of Products V8500
& V8550.
The MagneHis™ Protein Purification System provides a simple, rapid and reliable method for the purification of polyhistidine-
or HQ-tagged proteins. Paramagnetic precharged nickel particles (MagneHis™
Ni-Particles) are used to isolate polyhistidine- or HQ-tagged
protein directly from a crude cell lysate of bacterial, insect or
mammalian cells or from culture medium using either a manual or
automated procedure. Using the manual protocol, polyhistidine- or
HQ-tagged protein can be purified using 1ml of culture of up to 6
O.D.600 of bacterial cells, or 2 × 106 insect or mammalian cells.
Samples can also be processed using a robotic platform for
high-throughput applications. The MagneHis™ System is useful for
screening multiple clones for
expression, optimizing expression conditions (temperature, media,
host strain,
etc.) and the initial screening of mutant clones.
Bacterial, insect or mammalian cells containing a polyhistidine- or
HQ-tagged protein can be lysed directly in the culture medium using the
provided
FastBreak™ Cell Lysis Reagent, 10X, or by adding 1X FastBreak™
Cell Lysis
Reagent to cell pellets. MagneHis™ Ni-Particles are then added to
the lysate. In
addition, tagged proteins secreted into the medium of insect or
mammalian
cells can be purified without interference from serum in the medium.
Polyhistidine- or HQ-tagged proteins bind to the MagneHis™
Ni-Particles in a
matter of minutes. Unbound proteins are washed away, and the target
protein
is recovered by elution with imidazole. Polyhistidine- or
HQ-tagged
proteins can be purified under native and denaturing conditions.
Additionally, HQ-tagged proteins may elute with a lower concentration of imidazole
(50–100mM) compared to polyhistidine-tagged proteins.
|