The GloMax®-Multi+ Detection System with Instinct™ Software combines the superior performance expected from single-mode instruments with the functionality of multiple modes. Detection modes include Fluorescence Intensity, Luminescence and UV-Visible Absorbance. The GloMax®-Multi+ Detection System accepts 6-, 12-, 24-, 48-, 96- and 384-well plates and is configured with a factory-installed shaker that allows for either linear or orbital shaking. The GloMax®-Multi+ Detection System may be purchased with an optional heater allowing precise temperature control from 2°C above ambient temperature to 45°C. The GloMax®-Mu...
Expand to Read More »
The GloMax®-Multi+ Detection System with Instinct™ Software combines the superior performance expected from single-mode instruments with the functionality of multiple modes. Detection modes include Fluorescence Intensity, Luminescence and UV-Visible Absorbance. The GloMax®-Multi+ Detection System accepts 6-, 12-, 24-, 48-, 96- and 384-well plates and is configured with a factory-installed shaker that allows for either linear or orbital shaking. The GloMax®-Multi+ Detection System may be purchased with an optional heater allowing precise temperature control from 2°C above ambient temperature to 45°C. The GloMax®-Multi+ Detection System has a touch screen interface with an easy-to-use software program. The Instinct™ software puts data analysis capabilities on the touch screen. Label samples and see analyzed data and graphs from the instrument. The protocol composer allows complex protocols to be easily developed by combining multiple technologies into one experiment. In addition, protocols for a variety of Promega and common laboratory assays are pre-installed. The system works alone as a standalone workstation in the laboratory, freeing computing resources from data capture, so more resources can be directed toward other applications.
The GloMax®-Multi+ Detection System with Instinct™ Software is made up of a base unit available in two different formats, one with shaking (E8032) and one with heating and shaking (E9032), plus modular detection and functional units, allowing a flexible solution that can be expanded over time. Luminescence, fluorescence and absorbance reading modules are available as well as an optional injector system (used with the luminescence detection module only).
Luminescence Module: An advanced head-on photon-counting photomultiplier tube (PMT) provides unmatched signal-to-noise ratios, beating most standalone luminometers. The luminescence module can detect as little as 3 × 10–21 moles of luciferase, covering a dynamic range over 8 logs. A dual-masking system minimizes well-to-well cross-talk.
Fluorescence Module: Application-optimized Optical Kits simplify fluorescence operation while maximizing performance. Long-lived LED-based excitation lights minimize maintenance and variability in intensity. LED usage increases sensitivity by fully exciting the fluorophore and reducing nonspecific light leakage, a problem often found when using broad-spectrum light sources. The UV, Blue, Green, Red and AFC Optical Kits are included with the Fluorescence Detection Module.
- UV (Ex: 365nm, Em: 410–460nm)
- Blue (Ex: 490nm, Em: 510–570nm)
- Green (Ex: 525nm, Em: 580–640nm)
- Red (Ex: 625nm, Em: 660–720nm)
- AFC (Aminofluorocoumarin; Ex: 405nm, Em: 495–505nm)
Visible Absorbance Module: A 6-position filter wheel with 2 open positions ensures flexibility for a wide range of applications. An LED-based visible spectrum light source minimizes maintenance and variability. The Visible Absorbance Module has a reading range of 0–5.0 OD with an accuracy that deviates less than 2%. This module comes with filters for reading 450, 560, 600 and 750nm. A 490nm filter is available as an accessory.
UV-Visible Absorbance Module: This module comes with a 6-position filter wheel that includes filters for measuring 260, 280, 450, 560, 600 and 750nm. These filters accommodate UV DNA and protein quantitation in addition to ELISA and protein assays. Like the Visible Absorbance Module, you can customize the UV-Visible Absorbance Module by substituting a filter of your choice into either of two removable filter paddles.
Operation of the GloMax®-Multi+ Detection System can be performed entirely through the touch screen. Data can be saved on the instrument and moved via the included USB flash drive.
Learn more about the GloMax®-Multi+.
Compare with our other GloMax® Luminometers.
Features - Benefits
- Instinct™ Software: Label samples and see analyzed data and graphs on the touch screen.
- Measurement Techniques: Luminescence, fluorescence and UV-Vis absorbance capabilities.
- Flexible Modular Configuration: Modular system grows with your needs.
- Microplate Formats: Reads 6-, 12-, 24-, 48-, 96- and 384-well plate formats.
- Factory-Installed Shaker: Enables shaking in either linear or orbital mode.
- Optional Heater Available: Allows precise temperature control from 2°C above room temperature to 45°C +/– 0.75°C.
- Dedicated Luminometer Performance: Sensitive to approximately 3 × 10–21 moles of luciferase with over 8 logs of dynamic range.
- Multiplex Cell-Based Assays: Obtain more data from each experiment.
- Engineered to Minimize Sample Cross-Talk: Expect reliable results in all read modes.
- Simple-to-Use Drag-and-Drop Protocol Composer: Easily develop complex protocols.
- Convenient, Standalone Operation: Eliminate bottlenecks and free analysis resources.
- Injector Systems: Both single and dual injectors are available.
Applications
- Reporter assays.
- Cell viability assays.
- Apoptosis assays.
- Protease assays.
- Kinase assays.
- ADME assays.
- Protein assays.
- ELISA.
Notes
Cat.# E8032 and E9032 cannot be sold separately and must be purchased with at least one detection module (Cat.# E8041, E8051, E8061 or E9061).
« Collapse Content