Focus: High-Throughput DNA PurificationAutomated Isolation of Genomic DNA Using Promegas Wizard® SV 96 DNA Binding Plates on the Beckman Biomek® 2000
By Terri Grunst, B.S.
|
|||||||||||||||||||||||||||||||||||
Table 1. Protocols for Lysate Preparation from Indicated Sample Types. |
|
Procedure |
|
Mouse Tail |
1. Digest each 0.5cm
mouse-tail snip with 200µl Nuclei Lysis Solution, 48µl EDTA (0.5M) and 17.5µl
Proteinase K (20mg/ml) solution. Vortex to mix. |
Plant Tissue |
1. Crush 100mg of plant
tissue to a fine powder in liquid nitrogen with a mortar and pestle. |
CHO Cells |
1. Grow cells in a 96
well tissue culture plate at a density of 1 x 106 cells per well. |
Whole Blood |
1. Add 400µl of Lysis
Buffer (SV RNA Lysis Buffer plus 1% Triton® X-100) to 200µl of whole blood.
Vortex to mix. |
Cheek Swab |
1. Scrape the inside of
the cheek with a clean pipette tip. |
Automated Isolation of Genomic DNA
Sample lysate preparation will differ depending on the sample type for isolating genomic DNA. Table 1 briefly describes the lysate preparation for each sample type tested for this report. Once the lysate is prepared, genomic DNA isolation is performed on the Beckman Biomek® 2000, using a single protocol for all sample types.
For genomic DNA, 150µl of prepared lysate is placed into the well of a 96 well plate and the plate is placed on the deck of the Beckman Biomek® 2000. As shown in Figure 1, the remainder of the Biomek® 2000 deck is assembled according to the programs initial deck configuration. Once configured, the Biomek® program is initiated and takes approximately one hour per 96 well plate (up to 96 samples) (see Table 2).
Table 2. Biomek® 2000 Program for Isolation of Genomic DNA. |
|
Step |
Process |
1 |
Biomek® 2000 transfers 150µl of sample lysate from the 96 well sample plate to the Wizard® SV 96 DNA Binding Plate. The sample lysate is pulled through the plate by vacuum and the DNA binds. |
2 |
The samples are washed twice with 500µl of Wizard® SV 96 Wash Solution containing 60% ethanol, using the Wash 8 tool. |
3 |
The binding plate is dried briefly by vacuum. |
4 |
The binding plate is transferred from the B6 to the A6 vacuum manifold position where it is placed on top of an elution plate fitted with a vacuum manifold collar. |
5 |
DNA is recovered in the elution plate by addition of Nuclease-Free Water (75µl) to the binding plate. |
Analysis
Purified genomic DNA is eluted in 75µl of Nuclease-Free Water (Cat.# P1193). For mouse tail, plant tissue and tissue culture cell samples, a 20µl aliquot was analyzed by agarose gel electrophoresis (Figure 2).
Quality of the genomic DNA was assessed by PCR. One microliter of the genomic DNA was used for PCR amplification in a 50µl reaction. Specific oligonucleotide primers were used to target genomic DNA sequences: IL-1b gene for mouse tail, b-actin for CHO cells, and a noncoding region of chloroplast DNA (1) for tomato leaf samples (Figure 3).
Sample cross-contamination was investigated by assaying an array of blood and cheek swab samples, alternating with water controls, in a 96 well plate. A prothrombin transcript was targeted by PCR in samples from all wells. As evident in Figure 4, no sample-to-sample contamination was observed in this experiment.
Discussion
An advantage of this automated genomic DNA isolation system is the flexibility of the procedure. In this study we isolated genomic DNA from a good representation of some common sample types. Types varied from those easily processed (e.g., tissue culture cells), to more difficult ones (e.g, whole blood and plant tissue).
Purified genomic DNA isolated using this automated procedure consists of largely intact genomic DNA of greater than 23kb. The isolated DNA contains trace amounts of RNA, which can be removed easily by adding 1µl of RNase ONE Ribonuclease (Cat.# M4261) directly to the eluted DNA or by adding 100µl per 10ml Nuclease-Free Water used to elute the DNA. The purified genomic DNA can be amplified by PCR and is suitable for use in many downstream applications. The processing time for isolation of genomic DNA is approximately one hour per 96 well plate, with no manual intervention. Multiple samples can be processed in one run with no cross-contamination.
A potential limitation of this automated genomic DNA isolation system is in processing viscous lysates. Sample lysates that contain excessive amounts of cellular debris will be viscous and will not move easily through the Wizard® SV 96 DNA Binding Plate. These samples may even clog the plate wells. For the samples processed in this study, the lysate preparation and solution volumes were optimized. Optimization should be considered for other samples to achieve successful genomic DNA isolation.
Conclusion
Genomic DNA can be isolated in a high-throughput format using Promegas Wizard® SV 96 DNA Binding Plate on the Beckman Biomek® 2000. The automated procedure described here can be used to isolate quality genomic DNA >23kb that is ready for downstream applications. We demonstrated the flexibility of the procedure by isolating genomic DNA from multiple sample types. Importantly, no cross-contamination was detected using this automated procedure.
Reference